Anytime Help Center

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Support
  • Guest
  • Log In
English (US)
US English (US)
DE German
CN Chinese
MX Spanish (Mexico)
Chinese (Simplified)
  • AKG
    Microphones Wireless Integrated Systems Automatic Mixers Headphones Discontinued Products (AKG) General AKG Inquiries Certifications (AKG)
  • AMX
    Networked A/V Distribution (AVoIP) Traditional A/V Distribution Video Signal Processing Architectural Connectivity User Interfaces Control Processing Power (AMX) Programming (AMX) Software (AMX) Discontinued Products (AMX) General AMX Inquiries Certifications (AMX)
  • BSS
    Soundweb™ Omni Soundweb™ London Soundweb™ Contrio™ Software (BSS) Discontinued Products (BSS) General BSS Inquiries Certifications (BSS)
  • Crown
    CDi DriveCore Series CDi Series Commercial Series ComTech Series DCi DriveCore Series I-Tech HD Series XLC series XLi Series XLS DriveCore 2 Series XTi 2 Series Discontinued Products (Crown) Software (Crown) General Crown Inquiries Certifications (Crown)
  • dbx
    CX Series 500 Series DriveRack Personal Monitor Control ZonePRO Zone Controllers FeedBack Suppression Microphone Preamps Dynamics Processors Crossovers Equalizers Software (dbx) Discontinued Products (dbx) General dbx Inquiries Certifications (dbx)
  • Flux::
    Immersive Processing Analysis Subscriptions
  • JBL
    Cinema Sound Installed Live Portable Tour Sound Recording & Broadcast Software (JBL) Discontinued Products (JBL) Video Manual Series (JBL) General JBL Inquiries Certifications (JBL)
  • Lexicon
    Plugins Effects Processors Cinema Discontinued Products (Lexicon) Video Manual Series (Lexicon) General Lexicon Inquiries Certifications (Lexicon)
  • Martin
    Atomic ELP ERA Exterior MAC P3 VC VDO Tools Discontinued Products (Martin) General Martin Inquiries Certifications (Martin)
  • Soundcraft
    Digital Analog Connected Analog Only Discontinued Products (Soundcraft) Video Manual Series (Soundcraft) General Soundcraft Inquiries Certifications (Soundcraft)
  • General HARMAN Inquiries
    Dante
+ More
  • Home
  • AMX
  • Discontinued Products (AMX)

How to Setup IIS & Remotely Load Firmware to the AcendoBook

Written by Will Fraser

Updated at January 9th, 2026

Table of Contents

Question:   Answer: Setting up IIS & remotely loading firmware: How to access AcendoBook Panel via SSH: Note: How to Enable IIS on your PC: Note: How to remotely load firmware to panel: Note:

Question:  

How do I Setup IIS & Remotely Load Firmware to the AcendoBook?


Answer:

Setting up IIS & remotely loading firmware:

The AcendoBook has the capability to remotely load firmware from a web server.  This server has to be accessible from the network the panel is on and require no authentication.  You can use any SSH client but PuTTy is free and available from PuTTy.org, this guide will use PuTTy.

How to access AcendoBook Panel via SSH:

  1. Disable pseudo-terminal.
    1. If using PuTTy: Open SSH dropdown>Select TTY>Select check box for “Don't allocate a pseudo-terminal".
  2. Enable session logging in your client.
    1. In PuTTY, select Logging.
    2. Select All Session Output.
    3. Click Browse to find a location to save the file and give it a name.
  3. Once you have disabled the pseudo-terminal and enabled session logging, open the SSH connection to the panel.
  • Default login: amx
  • Default Password: 1988 

Note: 

If the password was changed on the panel, the SSH password will be the password used to access panel settings.

 

 

How to Enable IIS on your PC:

  1. Select Start>Type “Turn Windows Features On or Off”
    1. Check the "Internet Information Services" box. Click OK.   Allow installation to process and close all dialogs
  2. Select Start>Type "IIS">Select Internet Information Services Manager
  3. In IIS click the triangle beside your machine name in the Connections panel on the left of the IIS Manager dialog.  Expand "Sites", Select “Default Web Site”
  4. Select MIME Types, Select "Add..." in Actions pane and enter this info:
    1. File Name Extension: .kit
    2. MIME Type: application/x-zip-compressed
  5. Open a File Explorer window and navigate to "C:\inetpub\wwwroot", move the .kit file to this directory

Note:

​If your panel is an MD-702/1002 there is a + in the firmware file name that is not supported by the WEBU command.  You will need to rename the firmware file to remove the + when adding it to the wwwroot directory.

 

 

How to remotely load firmware to panel:

  1. Open an SSH connection to panel
  2. Send "webu http://[youriphere]/nameofkitfile" 

Note: 

You should see a progress bar pop up almost immediately -- if you do not see this, the connection from panel to PC/Server did not work.  The panel will need to be rebooted before attempting another download.​

 

 

 

Related Videos

questions guide

Was this article helpful?

Yes
No
Give feedback about this article

Table of Contents

Question:   Answer: Setting up IIS & remotely loading firmware: How to access AcendoBook Panel via SSH: Note: How to Enable IIS on your PC: Note: How to remotely load firmware to panel: Note:

Related Articles

  • Enabling EWSTrace and Logging on AcendoBook
  • Keeping Keyboard Number Lock Enabled on Acendo Core
  • RMS and Java Versions

Related Articles

  • Enabling EWSTrace and Logging on AcendoBook
  • Keeping Keyboard Number Lock Enabled on Acendo Core
  • RMS and Java Versions
Copyright © HARMAN Professional. All rights reserved. Privacy Policy | Terms of Use
Expand