Anytime Help Center

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Support
  • Guest
  • Log In
English (US)
US English (US)
DE German
CN Chinese
MX Spanish (Mexico)
Chinese (Simplified)
  • AKG
    Microphones Wireless Integrated Systems Automatic Mixers Headphones Discontinued Products (AKG) General AKG Inquiries Certifications (AKG)
  • AMX
    Networked A/V Distribution (AVoIP) Traditional A/V Distribution Video Signal Processing Architectural Connectivity User Interfaces Control Processing Power (AMX) Programming (AMX) Software (AMX) Discontinued Products (AMX) General AMX Inquiries Certifications (AMX)
  • BSS
    Soundweb™ Omni Soundweb™ London Soundweb™ Contrio™ Software (BSS) Discontinued Products (BSS) General BSS Inquiries Certifications (BSS)
  • Crown
    CDi DriveCore Series CDi Series Commercial Series ComTech Series DCi DriveCore Series I-Tech HD Series XLC series XLi Series XLS DriveCore 2 Series XTi 2 Series Discontinued Products (Crown) Software (Crown) General Crown Inquiries Certifications (Crown)
  • dbx
    CX Series 500 Series DriveRack Personal Monitor Control ZonePRO Zone Controllers FeedBack Suppression Microphone Preamps Dynamics Processors Crossovers Equalizers Software (dbx) Discontinued Products (dbx) General dbx Inquiries Certifications (dbx)
  • Flux::
    Immersive Processing Analysis Subscriptions
  • JBL
    Cinema Sound Installed Live Portable Tour Sound Recording & Broadcast Software (JBL) Discontinued Products (JBL) Video Manual Series (JBL) General JBL Inquiries Certifications (JBL)
  • Lexicon
    Plugins Effects Processors Cinema Discontinued Products (Lexicon) Video Manual Series (Lexicon) General Lexicon Inquiries Certifications (Lexicon)
  • Martin
    Atomic ELP ERA Exterior MAC P3 VC VDO Tools Discontinued Products (Martin) General Martin Inquiries Certifications (Martin)
  • Soundcraft
    Digital Analog Connected Analog Only Discontinued Products (Soundcraft) Video Manual Series (Soundcraft) General Soundcraft Inquiries Certifications (Soundcraft)
  • General HARMAN Inquiries
    Dante
+ More
  • Home
  • BSS
  • Software (BSS)
  • HiQnet Audio Architect

AUDIO ARCHITECT Troubleshooting a BSS Device Not Able to Load a Configuration

Written by Gary Brindley

Updated at January 22nd, 2026

Table of Contents

​Intr​​oduction​ Check the Network Configuration​ Disco​​nnect VPNs Turn o​ff Firewalls Connect ​Directly to Device Disa​ble Secondary Network Ports Design File Configuration Try loading a blank Design fil​​e Is the De​​vice Dante Enabled? Try Recompiling the Device Configuration Device Configuration Is the De​​​vice Cobra Net Enabled? (BLU320, BLU800) Verify the FTP is ope​​n on the device. sing the London Confi​gurator to verify the port is open

​Intr​​oduction​

​In this guide we cover the steps necessary to troubleshoot a device not accepting a configuration. When Audio Architect encounters an error loading a device configuration the device will show up in red in the Venue Explorer window after the synchronization process.

When troubleshooting the loading process we can break the categories to check into Network, Design File and Device Configuration.

 

We can then further break these categories down into things that are known to present problem and create a list of tasks based to come up with a simple flow chart to troubleshooting a system.

Check the Network Configuration​

Network configuration includes both the PC that the software is running and the physical network and switches that are connected. You will want to verify the PC is on same subnet as the DSP. If you are using wireless you will want to verify you have a solid connection.

Disco​​nnect VPNs

You will want to disconnect any VPN connections when troubleshooting since many VPN clients will actually block local network ports to prevent unauthorized access.

Turn o​ff Firewalls

Firewalls are designed to network ports to prevent access in order to protect you. However a misconfigured firewall can actually block the incoming and outgoing FTP traffic. We recommending turning off any firewall when trying to determine the root cause of a device not loading. https://support.microsoft.com/en-us/help/4028544/windows-10-turn-microsoft-defender-firewall-on-or-off

Connect ​Directly to Device

Most modern computers have a gigabit network port which means they can auto negotiate without a switch. Connecting directly to the device rules out ports being blocked by a network switch. It also rules out possible issues with network infrastructure. If you can load a device when conn​ected directly to it then you will want to verify the IT depart is not blocking FTP and check cables.

Disa​ble Secondary Network Ports

One thing that has been observed on some computers is they have trouble when trying to talk on more than one network port at a time. This is especially true if both ports have overlapping subnets for their IP address ranges or if they share a MAC address between their Wireless and Wired NICs.

Design File Configuration

In some cases it is possible for the design file to cause issues when loading devices. This is usually either a problem with how Dante is configured in the file or even a possible problem with how configuration compiled.

Try loading a blank Design fil​​e

If the device will load a blank configuration then it points to something in the Audio Architect design file. If the device will not take a blank design file then this usually indicates the problem lies with the device configuration and not the design file.

Is the De​​vice Dante Enabled?

If the device is Dante enabled. Check the properties of each Dante block in the processor verify the routing type.

Selecting Use Dante Controller will load the device normally and not try and load routes to the Brooklyn card via the Dante Network

Selecting Use Audio Architect, the software will try and directly communicate with the each Dante card via the Dante network and load the routings on the card. If the Brooklyn card is not reachable on the network by the machine running Audio Architect, the software will time out and show you the red highlighted device indicating it was not able to load the Dante routes.

If the device is Dante enabled also verify the Brooklyn II card is booting up and showing in Dante Controller. If the Brooklyn card is malfunctioning then then device may hang up when it tries to send the Device and channel names to the Brooklyn II card.

If you find the card is not working correctly, it may be necessary to run the Audinate Firmware manager to bring the card out of failsafe mode. You can download firmware update manager here: https://my.audinate.com/latest-firmware-update-manager

Try Recompiling the Device Configuration

If there is a problem in the compiled code you can force recompile a box by simply adding and removing a DSP object or wire then go back online and try loading the DSP.

If the DSP still doesn't load the file you may need to use process of elimination to determine what part of the code is causing the problem.

Try removing all of the processing blocks and load the configuration. If this works then work backward and load half of the processing blocks to determine which block may be causing the issue.

Reset the properties on the input and output cards by copying parameters over from a new DSP without any settings. If copying the properties solves the problem then try re-entering the properties

Device Configuration

Device configuration deals with changes made to the device that might prevent the file from loading or the configuration from becoming active.

Is the De​​​vice Cobra Net Enabled? (BLU320, BLU800)

Cobra Net devices will throw an error on loading if the CM-1 card name has been changed in Cobra Net Discovery.

You can download Cobra Net Discovery here; www.cobranet.info

Once you install Cobra Net discovery, you will need to set correct network adapter under Tools>Options. Set this to the adapter that is connected to the Cobra Net network or connect directly to the CM-1 card.

Once this is set should start discovery devices. You can right click on a device to set its IP address so it is reachable by the computer.

You will need to enable SNMP under the Tools>Preferences Menu

You should then start to discover devices

If the device doesn't show an IP address you can assign one in discovery by right clicking the device. It is recommended that you connect directly to the device when doing this so you don't assign the wrong device an IP.

Double click on the Cobra Net card for the London Device and you will see the configuration window. Click on the advanced button.

The name should be blu 48k or blu 96k if you are running 96k (it is case sensitive). If it has been changed to something else you will need to change it back. Click ok to close Cobra Net Discovery and reboot the device.

Once the device is discovered load the file again.

Verify the FTP is ope​​n on the device.

Run Power Shell and telnet to the device

Select Power Shell

Connect to the device using Windows Telnet (see Using Telnet in Soundweb London for more info)

Note if the device has had its telnet port closed then the only way to reset the port is from serial using the London Configurator (see next step).

Type openport ftp

The device will respond back with the port status.

Reboot the unit by typing reboot.

Once the unit has rebooted the port should be open.

Try loading the device again

sing the London Confi​gurator to verify the port is open

Connect to the device with a Null Modem Cable

Run London Configurator. (See link)

Select the correct com port and refresh.

Configurator should fill in the device information

Make sure the port status is checked for FTP. If not check the port(s) and send settings

The device will reboot

Try loading the design

Verify device filesystem

If there is still problem try a factory reset by connecting to the device with telnet and using the formatflash command. (See using Telnet with Soundweb London)

If the device still doesn't load there may be another computer related issue or a hardware issue on the device. Try the above steps with a second computer if that fails there could be a problem with the device itself so try a second device.

Related Videos

configuration issues bss troubleshooting

Was this article helpful?

Yes
No
Give feedback about this article

Table of Contents

​Intr​​oduction​ Check the Network Configuration​ Disco​​nnect VPNs Turn o​ff Firewalls Connect ​Directly to Device Disa​ble Secondary Network Ports Design File Configuration Try loading a blank Design fil​​e Is the De​​vice Dante Enabled? Try Recompiling the Device Configuration Device Configuration Is the De​​​vice Cobra Net Enabled? (BLU320, BLU800) Verify the FTP is ope​​n on the device. sing the London Confi​gurator to verify the port is open

Related Articles

  • Extracting the DSP Configuration in a BSS Soundweb London Device
  • PA2 Manufacturing Updater & Reset Procedures

Related Articles

  • Extracting the DSP Configuration in a BSS Soundweb London Device
  • PA2 Manufacturing Updater & Reset Procedures