Anytime Help Center

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Support
  • Guest
  • Log In
English (US)
US English (US)
DE German
CN Chinese
MX Spanish (Mexico)
Chinese (Simplified)
  • AKG
    Microphones Wireless Integrated Systems Automatic Mixers Headphones Discontinued Products (AKG) General AKG Inquiries Certifications (AKG)
  • AMX
    Networked A/V Distribution (AVoIP) Traditional A/V Distribution Video Signal Processing Architectural Connectivity User Interfaces Control Processing Power (AMX) Programming (AMX) Software (AMX) Discontinued Products (AMX) General AMX Inquiries Certifications (AMX)
  • BSS
    Soundweb™ Omni Soundweb™ London Soundweb™ Contrio™ Software (BSS) Discontinued Products (BSS) General BSS Inquiries Certifications (BSS)
  • Crown
    CDi DriveCore Series CDi Series Commercial Series ComTech Series DCi DriveCore Series I-Tech HD Series XLC series XLi Series XLS DriveCore 2 Series XTi 2 Series Discontinued Products (Crown) Software (Crown) General Crown Inquiries Certifications (Crown)
  • dbx
    CX Series 500 Series DriveRack Personal Monitor Control ZonePRO Zone Controllers FeedBack Suppression Microphone Preamps Dynamics Processors Crossovers Equalizers Software (dbx) Discontinued Products (dbx) General dbx Inquiries Certifications (dbx)
  • Flux::
    Immersive Processing Analysis Subscriptions
  • JBL
    Cinema Sound Installed Live Portable Tour Sound Recording & Broadcast Software (JBL) Discontinued Products (JBL) Video Manual Series (JBL) General JBL Inquiries Certifications (JBL)
  • Lexicon
    Plugins Effects Processors Cinema Discontinued Products (Lexicon) Video Manual Series (Lexicon) General Lexicon Inquiries Certifications (Lexicon)
  • Martin
    Atomic ELP ERA Exterior MAC P3 VC VDO Tools Discontinued Products (Martin) General Martin Inquiries Certifications (Martin)
  • Soundcraft
    Digital Analog Connected Analog Only Discontinued Products (Soundcraft) Video Manual Series (Soundcraft) General Soundcraft Inquiries Certifications (Soundcraft)
  • General HARMAN Inquiries
    Dante
+ More
  • Home
  • Martin
  • MAC
  • MAC Viper Legacy

Discharge Lighting Shutdown Guidelines

Technical Support Guide

Written by Peter Stauber

Updated at February 2nd, 2026

Table of Contents

Brand: Models: Discharge Lighting Shutdown Guidelines

Brand:

Martin


Models:

MAC Viper Series, MAC Viper Profile, MAC Viper Performance, MAC Viper Wash, MAC Viper Wash DX, MAC Viper AirFX


Discharge Lighting Shutdown Guidelines

Martin Professional™ are keen to ensure that customers obtain the best possible performance from Martin™ products while at the same time keeping operating costs and environmental impact to a minimum. We are therefore issuing the following guidelines to help customers manage discharge lighting as economically as possible.

Discharge lighting fixtures from Martin™ are built to withstand a reasonable number of mains power on/off cycles with no detrimental effect on the fixture, its performance or its lifetime.

If light output from fixtures is not required for a period of one hour or more, it is generally a good idea to cut lamp power from the control desk.

For longer periods when fixtures will not be in use, it is both safe and normal to cut mains power to the fixture in order to reduce power consumption. When you do this, first cut power to the lamp from your control desk but leave power applied to the fixture so that the thermostatically regulated cooling systems can continue to stabilize temperatures. After 5 minutes you can then cut power to the fixture completely.

During normal operation, all Martin Professional™ fixtures fitted with an electronic ballast will automatically reduce lamp power when the shutter has been closed for 10 seconds. To avoid unnecessary power consumption, you should therefore ensure that all shutters are fully closed during blackouts.

Most double-ended lamps are specified to 600 ignitions during their lifetime. Using less than 600 ignitions during the lamp lifetime will not have any negative effect on the lamp’s performance. However, exceeding this figure will begin to reduce the overall lifetime of the lamp, so excessive strikes are undesirable.

Martin™ fixtures’ personality settings can be configured so that a command from the control desk is required to power the lamp on after mains power is applied. We recommend that you use this feature in order to minimize power consumption and hours of lamp operation. When you do this, power the lamp on approximately 15 minutes before the fixture is used so that the lamp has time to stabilize at its correct operating temperature.


 

Related Videos

framework blueprint

Was this article helpful?

Yes
No
Give feedback about this article

Table of Contents

Brand: Models: Discharge Lighting Shutdown Guidelines